temperature_humidity_and_pressure_meter_to_mqtt_bme280 [08.01.2019 00:51] – [OpenMQTTGateway] Pascal Sutertemperature_humidity_and_pressure_meter_to_mqtt_bme280 [08.01.2019 01:34] (current) Pascal Suter
Line 9: Line 9:
 the [[https://github.com/1technophile/OpenMQTTGateway/wiki/ESP8266-I2C-Modules|hardware wiring]] by default looks like this:  the [[https://github.com/1technophile/OpenMQTTGateway/wiki/ESP8266-I2C-Modules|hardware wiring]] by default looks like this: 
 ^ I2C Module ^ NodeMCU / ESP8266 ^ ^ I2C Module ^ NodeMCU / ESP8266 ^
-| Vcc  |Vu (5V) |+| Vcc  | 3.3V |
 |GND | GND | |GND | GND |
 |SCL |D1| |SCL |D1|
Line 22: Line 22:
 so lets try also  so lets try also 
 ===== Tasmota ===== ===== Tasmota =====
 +also check out my detailed description for the [[sonoff]] setup. basically download the latest [[https://github.com/arendst/Sonoff-Tasmota/releases|release]] and then copy the lib folder into your arduino ''sketchbook/libraries'' folder. then edit the ''my_user_config.h'' file and make sure the ''#define USE_BMP'' is enabled. also sest the ''#define MODULE'' to ''WEMOS''. as a side-note: this will be called "Generic" in the web-interface but in the source code it's still called WEMOS. 
 +
 +the [[https://github.com/arendst/Sonoff-Tasmota/wiki/Wemos-D1-Mini-and-BME280-Temperature,-Humidity-and-Pressure-Sensor|hardware setup]] looks like this (note, the scl and sda lines could be changed to match OMG for example or vice versa, however, i have it on a breadbord, so i simply changed the patch wires): 
 +^ I2C Module ^ NodeMCU / ESP8266 ^
 +| Vcc  |3.3V |
 +|GND | GND |
 +|SCL |D4|
 +|SDA|D3|
 +|ADD |N/C (Not Connected|
 +
 +despite selecting the WEMOS module we still have to log into the web interface once the firmware is flashed and booted and go to ''Configuration --> configure module'' and then set ''D3 GPIO0 Button 1'' to I2C ''SDA(06)'' and ''D4 GPIO2'' to ''I2C SCL (05)''
 +
 +now you get a new reading every 5 minutes via MQTT. if you want to change this interval you can either do this in the ''my_user_config.h'' file or via mqtt or the "console" in the web interface by publishing this mqtt topic and value: 
 +  tasmota/sonoff/cmd/TelePeriod 30
 +this will set it to 30 seconds
 +
  